3M Attest 1292 Rapid Readout Biological Indicators 50/box

3M

(No reviews yet)
SKU:
3M1292
Check Warehouse Availability
3M Attest 1292 Rapid Readout 1 hour biological indicators contain Bacillus stearothermophilus spores for use with vacuum-assisted sterilization cycles
 

Product Details

  • Provides results in three hours
  • Self-contained biological indicators significantly reduce possibility of contamination, minimizing false positives and assuring more accurate results
  • Faster result time, making it possible to quarantine every load and eliminate recalls
  • System can help reduce the costs associated with fighting infections
  • Color-coded for quick reference and easy use
  • Test packs present a challenge to the sterilization process and meet AAMI test pack recommendations
  • Indicator is for 132°C vacuum assisted or 121°C gravity steam sterilizers. It provides assurance of sterility by challenging the sterilizer with quantifiable, highly resistant spores with results after one hour.

 

 

 

 

 

 

 

Biological indicators provide the best assurance of sterility by challenging the sterilizer with quantifiable, highly resistant Bacillus stearothermophilus spores. The system includes rapid readout biological indicators, disposable test packs, auto-readers and log books. Biological indicators are used for load control monitoring which is the process by which a load is monitored and released based on the result of a biological indicator (BI) in a test pack.3M Attest 1292 Rapid Readout Biological Indicators for 121° C (250° F) vacuum-assisted cycles Self-contained (BI) for 121° C (250° F) gravity/132° C (270° F) vacuum-assisted cycles consisting of a Bacillus stearothermophilus spore strip; sealed glass ampule with growth medium and dual indicator system; brown color-coded cap with holes for sterilant penetration and a hydrophobic filter as a bacterial barrier; and a chemical indicator on the label that changes from rose to brown when processed. After sterilization, the vial is "crushed" to join the growth media with the processed spore strip. The (BI) is incubated for three hours in the Attest 190 series auto-reader for a fluorescent reading. A red light indicates a positive result. 3M Attest 190 Series Auto-reader Dual function fluorescent reader/incubator for use with Attest rapid readout steam biological indicators. The incubator runs at 60° C (140° F). The (BI) is crushed in the crusher well, transferred to the incubation wells for 3 hours, then placed in the reader well until a red or green light goes on. The auto-reader must be calibrated with a processed, non-incubated test vial every 12 hours or anytime the calibration light comes on. The auto-reader UV lamp and starter must be changed every 6 months for the test results to be valid. In addition, a positive control (unprocessed BI) from the same lot and manufacturing date must be incubated daily and each time the auto-reader is calibrated.

 

Suggested Applications

Designed to monitor 250(deg)F/121(deg)C gravity and 270(deg)F/132(deg)C vacuum-assisted steam sterilization processes